Wfi Water Distribution System
The Wfi Water Distribution System is a high-quality electric water distribution system made from SS material. It ensures high purity level water supply that is essential in various industries like pharmaceuticals, food, and beverages, and many more.
The system operates on a voltage of 220-440 Volt (v) which is suitable for industrial use. The Wfi Water Distribution System is designed to provide a consistent and reliable water supply to your facility. It is a product that is both reliable and efficient for your water distribution needs.
Water for injection (WFI) may be obtained nowadays by one of the following ways:
- Thermal distillation
- Vapor Compression Distillation
- Combination of reverse osmosis, electrodeionization and ultrafiltration methods
Thermal Distillation:-
The process of thermal distillation is basing on evaporation and subsequent condensation of the feed water. The source of energy used to heat and evaporate the water in the process of thermal distillation can be technical steam under pressure of 4-8 bar or electric energy.
MFROT Water for Injection Plant is a fully automated, high-purity water production system designed for pharmaceutical industries. It produces water that meets USP and EP standards for sterility, endotoxin level, and conductivity.
The system integrates multiple purification technologies—including reverse osmosis (RO), ultrafiltration (UF), distillation, and continuous water circulation with sanitization—to ensure water purity and regulatory compliance.
This plant is ideal for pharmaceutical manufacturing, hospitals, laboratories, and research centers where sterile, pyrogen-free water is required.
Key Features :-
- Produces USP / EP / JP compliant Water for Injection (WFI).
- Fully automated PLC control with SCADA/HMI interface.
- Multi-stage purification: RO, UF, distillation, and hot water storage.
- Continuous recirculation to maintain water quality.
- Sanitizable SS316L piping with hygienic design.
- High-quality, corrosion-resistant storage tanks.
- Real-time monitoring of conductivity, temperature, flow, and pressure.
- Optional online microbial monitoring.
- Easy operation, cleaning, and validation
Key Features :-
| Parameter | Specification (Typical) |
|---|---|
| Capacity | 500 LPH – 5000 LPH (customizable) |
| Feed Water Source | RO Water / Purified Water |
| Purification Method | RO + UF + WFI Distillation / Continuous Recirculation |
| Material of Construction | SS316L (Tanks & Piping) |
| Temperature | Hot Water Sterilization 80–90°C |
| Conductivity | < 1.3 μS/cm (as per USP) |
| Endotoxin Level | < 0.25 EU/mL |
| Automation | PLC / SCADA / HMI |
| Piping & Fittings | Tri-clamp, sanitary-grade |
| Validation & Compliance | USP / EP standards |
Why Choose Our WFI Plant?
Meets USP, EP, and WHO standards.